Same site templates had lower centered late posterior cingulate SEEG error than other sites in six epilepsy patients with fixed gain and baseline control
We tested fixed voltage prediction after hippocampal complex stimulation in public OpenNeuro ds004696 version 1.0.1. Six selected patients had 14 posterior cingulate contacts, 19 source pairs, and 190 distinct pulses. The first five pulses formed a template. The next five formed a test mean. We centered each window and fixed the prediction gain at one. At 100 to 500 ms, same site templates had lower error than other site templates in all six patients. After a before pulse control, the mean gain was 5.285 times the training baseline energy. The 95% patient bootstrap interval was 2.315 to 8.496. The exact two sided sign p value was 0.03125, under independent patients and symmetric null signs. The average patient after error reduction against other sites was 68.78%. A later descriptive control also favored same site templates over zero voltage in all six patients. Fresh raw reconstruction matched all 1,881,408 voltage values. Independent code confirmed all seven analyses. Same site pulses occur in one clinical block, so brain state and artifacts can produce site differences. This follow-up uses the parent sample and does not establish a direct pathway or clinical biomarker. The package preserves data, code, source versions, results, and reproduction instructions.
stereoelectroencephalography · hippocampal stimulation · posterior cingulate cortex · voltage prediction · source specificity · epilepsy
References
5- usesSame site templates gave higher late posterior cingulate SEEG shape fits in six patients after hippocampal complex stimulation, with fitted scales and before-pulse control sci:sha256:ca9ddc0ddb4149c126a2e4677ccc55ff3a7bc1ce5f0c30ad22741319fd4870a5
We reused metadata selection helpers, pulse bins, and raw retrieval records from this package. Its test fitted voltage scales. It motivated our fixed gain voltage prediction test in the same six patients.
- usesSix of seven patients had larger corrected late posterior cingulate SEEG response energy after hippocampal complex than amygdala stimulation sci:sha256:b8a78a00fa46854fbd1804fe59a51f768a6de3a5f7793e876384384d856d24d0
The eight patient pulse bin inputs were preserved through this upstream package and the direct parent. We used these inputs for the fixed main selection and all planned checks.
- usesUnder pulse exchangeability within blocks, testing did not detect late posterior cingulate SEEG response change across ten hippocampal complex pulses in eight patients sci:sha256:17c9b08e401f6301a7d13c7f458da3d25678221ed6c6c87db14e33379c09052c
The pulse bin extraction method and raw source recipe reach this study through the parent package. We rebuilt the inputs from raw files and compared all array values.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
This is the recorded DOI for OpenNeuro ds004696 version 1.0.1, the source dataset used for the reported analyses.
- doi:10.1523/JNEUROSCI.2201-22.2023
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.