sciscape Publications
← All publications

Models fit to voice sounds did not pass a shared animal sound test in 20 iEEG patients and 16 fMRI adults

We tested whether acoustic tuning fit only to voice sound classes predicts response differences among animal sounds. Separate human studies supplied signed intracranial EEG and BOLD fMRI. Four people per study supplied development. A fixed ridge model then scored 20 other patients and 16 other adults. No animal sound entered fitting. Mean within-animal response correlation was 0.03979 in iEEG, with a 95% person interval of -0.01039 to 0.08997. The fMRI mean was 0.23447, with interval 0.20215 to 0.26679. Common animal-label tests gave p=0.1952 and p=0.0002. The fixed shared rule failed. Mean centered R2 was -7.94689 and -0.05489. All 20 electrical models and 13 of 16 BOLD models had worse centered squared error than a constant. One electrical sound had a supplied descriptor 200.8 voice-training SD from the mean. Omitting that sound reduced error, but mean centered R2 stayed negative. Stronger shrinkage improved both study means; it remains a descriptive check. The BOLD voice class includes one synthetic speech clip. Refitting over sound samples left BOLD error loss uncertain. We retain all failures and shared-sound uncertainty. The result limits this model under the tested panels. It does not establish absent acoustic coding, a causal modality difference or a common neural source. Different cohorts, labels, feature sets, source selection and measurement filters limit scope. The package preserves code, permitted inputs, source terms and hashes, fixed plans, all results, figures and repeat instructions.

auditory cortex · intracranial EEG · fMRI · acoustic encoding · animal sounds · human voice · domain transfer · prediction calibration · negative result

Admitted 3 citing publications

References

10
  1. usesFor fixed panels, readers trained on speech ranked other human voices above animal sounds in 20 iEEG patients and 16 fMRI adults sci:sha256:52e1af640ef1bde9f0d13b663fc7eb5e034cd4c61bc367532fc15aae8cef57dd

    We reuse its licensed electrical derivative, source records and MIT fMRI reader infrastructure. The new endpoint is response variation within animal sounds after voice-only fitting.

  2. usesWith clipped acoustic inputs, rank 2 models had lower mean test error than rank 1 for fixed panels from 20 iEEG patients and 20 fMRI adults sci:sha256:a7ebe1050fc6e865343e629ad39c22ef72edc352e2f1390afdc35c73a0231229

    This ancestor supplies electrical extraction and source provenance preserved by the direct input publication.

  3. Acoustic models predicted response differences within omitted sound categories in one iEEG panel and eight fMRI adults sci:sha256:5c06505284411649f8808f2e92a03fe96c9928cb7c5b391004f0030f358a3a94

    Its within-category acoustic prediction test motivates the new voice-only transfer test. The studies, models and electrical response types differ.

  4. usesdoi:10.5281/zenodo.20599001

    Version 1.1 supplies public electrical neural derivatives, acoustic features and labels under CC BY 4.0. The compact neural input is reused unchanged from the verified SCI source.

  5. usesdoi:10.1016/j.cub.2026.07.063

    Source human electrical study and graded voice sensitivity evidence.

  6. usesdoi:10.1152/jn.00588.2020

    Source B2021 fMRI recordings from 20 adults. Four supplied development; 16 supplied the fixed test.

  7. usesdoi:10.1371/journal.pbio.3002366

    Its public author archive supplies pinned B2021 response estimates and voxel metadata. Original arrays remain external.

  8. usesdoi:10.1016/j.cub.2022.01.069

    Its pinned public repository supplies BOLD sound labels and acoustic descriptors. Original MAT files remain external.

  9. doi:10.1371/journal.pcbi.1003412

    Prior acoustic encoding of human auditory responses.

  10. doi:10.7554/eLife.108795

    Recent human fMRI evidence for responses to nonhuman primate calls motivates the transfer question.

Cited by

3 publications

Public catalog entries on Sciscape.