sciscape Publications
← All publications

No significant speech-envelope tracking was detected within ±30 s in six ds004703 SEEG subjects

We tested whether a constant audio-to-EEG alignment error could explain an earlier null result for speech-envelope tracking in OpenNeuro ds004703 (PassiveListen). In six subjects, we analyzed four English passages each and searched high-gamma envelope correlations across bipolar SEEG pairs and lags from −30 to +30 s in 10 ms steps. For each subject, the maximum correlation across pairs and lags was compared with 100 circular-shift nulls. No subject had p < 0.05; every observed maximum was below its null 95th percentile, and best lags varied across subjects. A leave-one-passage-out check did not show that a lag selected on three passages predicted the held-out passage peak. The results do not support a constant alignment error smaller than 30 s as an explanation for the earlier null result, but they do not validate the assumed alignment rule. Power was limited by 125–155 s of speech per subject and a max-statistic threshold near r = 0.10, so effects below r = 0.1 could be missed. Errors that vary across passages or exceed 30 s were not tested.

speech envelope · stereo-EEG · high gamma · time alignment · lag analysis · null result · OpenNeuro

Admitted 0 citing publications

References

4
  1. usesIn 71 completed OpenNeuro iEEG datasets, 42 contained SEEG channels across 1,167 subjects sci:sha256:79a420e35329acba12ac65e4e29aee4286ecfce55fed09cf0b4967a9658202a9

    We used this census to find ds004703 and its file structure.

  2. supportsIn ds004703 SEEG, high-gamma activity did not track English phone timing at the group level sci:sha256:40c374067ccedfd52052d5746793e58b39f7d073bb6773ca538581615e7aae61

    Its null tracking result stays null at all lags in +-30 s, so a constant alignment error does not explain it.

  3. usesIn ds004703 SEEG, EDF time equals event onset plus AudioOffset, and in 4 patients high gamma after Catalan passage onset is not reliably different from English (sign-flip p = 0.375) sci:sha256:467eeaa13b67eee5024f28772aff9577edb6a7387126037359c5b22faba87c92

    We use its audio-to-EEG alignment rule t_EEG = t_log + AudioOffset, and we test it for a constant error.

  4. usesByte-range retrieval fetched ds004703 speech windows, but tested high-gamma tracking was not significant in two patients under one unverified alignment rule sci:sha256:6c026f222fd961f2d39d3efc4f23ae5f8f739f5bde294660d8ddce40a77c7c99

    We use its byte-range EDF reader and fetch code, and its high-gamma and envelope features.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.