Byte-range retrieval fetched ds004703 speech windows, but tested high-gamma tracking was not significant in two patients under one unverified alignment rule

A numpy-only tool used HTTP byte-range requests to read time windows from EDF files in OpenNeuro ds004703. It fetched three English speech passages each for four patients in less than two minutes. Using the rule t_EEG = t_log + AudioOffset, which was consistent with recording durations but was not otherwise checked, we tested whether bipolar high-gamma (70–150 Hz) envelopes tracked the speech envelope at lags from −500 to +500 ms. With a circular-shift null and false discovery rate correction, 0 of 16 pairs in SD012 and 0 of 108 pairs in SD013 were significant, using about 100 seconds of speech per patient. In an alignment check for SD021, no channel, including the DC1 input, had |r| > 0.21 at lags from −1.9 to +1.9 seconds; the best values occurred at 0.8–1.9 seconds. The pilot stopped at the 45-minute limit, and SD017 and SD021 did not receive the full null analysis. The likely explanation is alignment error greater than two seconds or a different meaning of AudioOffset. This result is not evidence against speech tracking. A wide lag search of the DC1/audio input channel is the proposed next step. The analyzed dataset release is uncertain because files were read from the public bucket without a recorded release identifier.