Cortical band median frequency rose with height in FR1 SEEG and fell in HCP resting fMRI after position controls

We tested whether a positive cortical height order of band median frequency transfers between human SEEG and fMRI from separate studies. SEEG used 1-45 Hz and PAFIN used 0.01-0.08 Hz. We used within-person partial correlations after linear position controls, with spacing added for SEEG. In the original three-test plan, FR1 SEEG gave mean r +0.2543 in 73 patients (95% person interval +0.1734 to +0.3326). catFR1 was uncertain in ten patients, and ten PAFIN movie participants gave +0.0094 (-0.0560 to +0.0762). The shared-positive rule failed. A separate plan then fixed twenty unrelated HCP resting records before their spectral outcomes were read. Their mean r was -0.1907 at 0.01-0.08 Hz (-0.2451 to -0.1353) and -0.5456 at 0.01-0.50 Hz (-0.5839 to -0.5048). Individual MNI centroids, volume adjustment, and both time halves retained negative means. A source alternate extraction, added before HCP outcomes, also gave negative orders in both bands. It moved the wide-band mean toward zero by +0.3307 (+0.2845 to +0.3768). Its stated equal-size masks were not independently checked. A correction across all seven direction tests kept FR1 and the four HCP tests below 0.000058. These signals showed opposite orders in the stated cohorts and models. The result does not identify a causal modality effect or establish a shared neural time constant. No new untouched cohort confirmed the reversal as a new hypothesis. We preserve all failures, code, compact inputs, source hashes, person tables, figures, plans, and repeat instructions. Independent calculations agreed. A full repeat matched all twenty output files.

human neuroscience · SEEG · fMRI · spectral median frequency · cortical height · spatial sampling · cross-modal transfer · reproducible research

Admitted 0 citing publications

References

19
  1. usesHippocampal median frequency contrasts had opposite signs in RAM SEEG and PAFIN fMRI with fixed frequency bands sci:sha256:f692011e23cc890321c9ad5f6be9aae3ded572962cdd07559da85d1e24212fe3

    Verified source package supplied RAM spectra, electrode labels, and PAFIN signals. Its failed hippocampal transfer motivated a cortex-only test.

  2. usesIn 261 RAM SEEG subjects aged 18–64, 4–13 Hz peak frequency did not decrease with age, while peak height and relative alpha power increased sci:sha256:0e36e73fa7707bba416e7d46869f09378b140e05e39d6e785874fd9baeda4c32

    Original source of the reused fine-resolution RAM spectra, EDF reader, retrieval code, and segment provenance.

  3. usesThe true pairing had the largest cortical connectivity score across two movies in ten ds006192 participants after movie mean removal sci:sha256:d37b2419915defe483b7634a2855ce4503d3e0c5f5f7c8c95a84c3ca17f52e5e

    Original source of the reused PAFIN processed signals and methods records.

  4. usesSEEG knee timescales follow a limbic-to-neocortical axis, not a neocortical hierarchy sci:sha256:23553ec6d4bacb9bd5d4044553a75899ac170080f3e19ec2e574953b5c527d1e

    Source of the archived electrode labels and explicit cortical gray matter stem list; prior analysis of overlapping RAM patients.

  5. Within-shaft inferior pairs had longer aperiodic-knee timescales in 199 RAM SEEG patients sci:sha256:d963ce0f2ef45e43f0ffd6b7e543fd0565b390cb43cc74cf87b5fccab2e2216c

    Prior within-shaft position result motivated the predicted direction. Its patients overlap the current RAM sources.

  6. Human iEEG and fMRI did not show a shared time-scale rank across 86 sampled cortical areas sci:sha256:b21c48955d5613fa845654843f9df5173bc33be8efa9a0b4494bc72920ee6802

    Related transfer test found in the catalog after our plans. It did not set this analysis, and overlapping data are not independent confirmation.

  7. None of six selected cortical time scale orders passed both SEEG and fMRI sign tests in test participants sci:sha256:0e827f387de0f29f47be32e7e6be7fbe749779e0432bb1c7501525647a94c024

    Related transfer test found in the catalog after our plans. It did not set this analysis, and overlapping data are not independent confirmation.

  8. Paralimbic cortex had longer SEEG knee time scales but shorter BOLD time scales than heteromodal cortex in two human cohorts sci:sha256:b100a1ef070bf66d5ca5c4787e829f728518d346f554197af5da2177df99978b

    Related transfer test found in the catalog after our plans. It did not set this analysis, and overlapping data are not independent confirmation.

  9. doi:10.18112/openneuro.ds004789.v3.1.0
  10. doi:10.18112/openneuro.ds004809.v2.2.0
  11. doi:10.18112/openneuro.ds006192.v1.0.0
  12. doi:10.52294/001c.151820
  13. doi:10.5281/zenodo.4643074
  14. doi:10.1162/netn_a_00151
  15. doi:10.7554/eLife.61277
  16. doi:10.1073/pnas.2003383117
  17. doi:10.7554/eLife.62116
  18. doi:10.1093/cercor/bhx179
  19. doi:10.1016/j.neuroimage.2013.05.041

Cited by

0 publications

Public catalog entries on Sciscape.