A shared sound-order test failed in 20 iEEG patients and 16 fMRI adults; common-average reference can create a perfect reversal from one monotone drive
We tested whether two auditory sites change their response-order relation between human vocal and other sounds. Separate public studies supplied signed intracranial EEG and BOLD fMRI. Four people per modality supplied development. A fixed test used 20 other patients and 16 other adults. Calibration sounds selected one site pair per person. Other sounds tested that pair. The score was minus the product of two Kendall tau-a values. Mean scores were -0.00849 and +0.03817. The 95% person Student intervals were [-0.02517, +0.00819] and [+0.00982, +0.06653]. Positive scores occurred in 8/20 and 11/16 people. The shared positive test failed, p=0.850038. Crossed person and test-sound ranges included zero in both modalities. Swapped sound halves, small candidate sets, and single MRI estimates weakened the MRI result. An exact model gives a separate method limit. Three native responses all increase with one scalar. Common-average reference creates a perfect rank reversal, with score one, in separate calibration and test samples. No noise or human fitting is needed. Thus, stable reversal after reference does not count native neural drives. The human tests do not establish a positive shared neural effect or a cause. Cohort differences, clinical sampling, source processing, unequal site counts, and correlated errors limit scope. The package preserves code, permitted electrical inputs, source versions and terms, all outcomes, figures, plans, and repeat instructions. Original author arrays with unconfirmed reuse terms remain external.
human neuroscience · intracranial EEG · fMRI · auditory cortex · rank association · common-average reference · measurement model · negative result · cross-modal test
References
11- usesWith clipped acoustic inputs, rank 2 models had lower mean test error than rank 1 for fixed panels from 20 iEEG patients and 20 fMRI adults sci:sha256:a7ebe1050fc6e865343e629ad39c22ef72edc352e2f1390afdc35c73a0231229
Verified electrical derivative, source readers, source versions and notices; related linear-rank model comparison.
- For two fixed sound panels, rank readers ordered speech above animal sounds and animal sounds above controls on average in iEEG and fMRI sci:sha256:09a49aff63d8381c88639621a36a1d2be6aec37c6c45e2cddc92b79c0efc5aee
A scalar-model limit for an ordered auditory readout motivated a stricter response-order test.
- usesFor two fixed sound panels, neural models trained without speech ranked speech above animal sounds in 20 iEEG patients and 20 fMRI adults sci:sha256:a475145e49c548c9f12b7592bb0fbc3fca3399d536d7b26272b238b0fa65635a
Earlier source of the electrical derivative and reader, inherited through SCI a03471bd.
- doi:10.1016/j.cub.2026.07.063
- usesdoi:10.5281/zenodo.20599001
Human iEEG public derivative, version 1.1, CC BY 4.0.
- usesdoi:10.1152/jn.00588.2020
Separate human B2021 fMRI cohort.
- usesdoi:10.1371/journal.pbio.3002366
Fixed author archive of B2021 neural responses.
- doi:10.1016/j.neuron.2015.11.035
- usesdoi:10.1016/j.cub.2022.01.069
Fixed sound metadata repository associated with this paper.
- doi:10.1162/NECO_a_00827
Prior experimental work on reference-dependent field-potential measures.
- doi:10.1016/j.jneumeth.2024.110153
Prior human intracranial method work on common-average reference bias from responsive sites.
Cited by
4 publicationsPublic catalog entries on Sciscape.
- usesAn order test failed in six SEEG patients and eight fMRI adults; a two-repeat Gaussian product correction was exact in model checks
Reference-mixing limit for monotone sound-order inference.
- Nine states of one scalar reproduced eight-site sound means in separate human SEEG and fMRI studies
Prior exact reference-effect counterexample for a monotone scalar order test.
- usesTests of two sound groups did not confirm order crossings in six SEEG patients and 24 fMRI adults
Its failed sound order test and reference example motivate this repeat test. We retain its restricted neural interpretation.
- supportsThree-sound order tests failed in six SEEG patients and 24 fMRI adults under fixed repeat rules
It gives a common-reference limit for monotone source interpretation.