At selected sites, four nonvocal axes captured extra speech-and-song repeat energy in six SEEG patients and 24 fMRI adults
We tested transfer of auditory response directions in separate public human studies. Four axes were fitted only to 128 source nonvocal sounds. Two other repeats tested 28 speech-and-song sounds. Target and spatial means were removed. Twenty fixed 16-site panels gave one score per person. Development used two SEEG patients and four fMRI adults. Reserved tests used six patients and 24 adults from two fMRI studies. Mean energy gains above the rank-four isotropic reference were 6.3659%, 8.9741% and 10.0267% of measured target energy. Their 95% person intervals were positive. All 30 people had positive scores. The stronger half-energy contrast was uncertain in SEEG, with three of six positive patients. The shared alignment rule passed after two-claim Holm correction, p=0.03125. The half-energy rule failed, p=0.65625. Common target-sound and person resampling kept positive alignment ranges. The assay uses separate person spaces and requires evidence in each cohort. Source selection used full sound panels and repeats. It can break the assumptions needed to infer latent signal energy. Constructed examples gave transfer with stable nuisance or disjoint neural sources under a common measurement map. Thus the result concerns selected processed responses. It does not establish shared neurons, neural rank or a cause. The package gives code, source versions and terms, plans, all outcomes, figures and repeat instructions. Original neural arrays remain external.
human auditory cortex · SEEG · fMRI · subspace transfer · independent repeats · sound responses · measurement · reproducible analysis
References
8- usesFor 165 fixed sounds, four-component models reduced repeat error in six SEEG patients and 24 fMRI adults sci:sha256:1ffb0217c831625cbe8fc949585c14c1f283f7e9f1b2113e69122af88fa9a59b
We reuse its MIT source preparation code and exact source pins. We test transfer to a sound group excluded from fitting.
- usesdoi:10.5281/zenodo.6544488
Public SEEG HGA source release, version v1.1. Original arrays remain external.
- usesdoi:10.1371/journal.pbio.3001675
Source SEEG study and measurement methods.
- usesdoi:10.1152/jn.00588.2020
Source B2021 fMRI study.
- usesdoi:10.1016/j.neuron.2015.11.035
Source NH2015 fMRI study and natural-sound panel.
- usesdoi:10.1371/journal.pbio.3002366
Source author archive of the two fMRI cohorts, with preprocessing and site-selection descriptions.
- doi:10.5281/zenodo.8349726
Versioned code archive associated with the public fMRI author data.
- Speech and song axes gave positive mean repeat scores for nine voice clips in SEEG and two fMRI cohorts sci:sha256:6720e49a50bda02902607508181e2616c7f5e48b21bceee56a2d3fcdc618bdae
Earlier preparation code lineage credited by our immediate SCI source. Original attribution is retained.
Cited by
7 publicationsPublic catalog entries on Sciscape.
- usesA fixed three-group area test failed across six SEEG patients and 24 fMRI adults despite mostly positive scores
Reuses MIT preparation code and exact public source pins.
- usesTests of two sound groups did not confirm order crossings in six SEEG patients and 24 fMRI adults
We reuse its MIT preparation code, source pins and selection rules. Our score differs from its linear subspace test.
- usesAt selected auditory sites, the top quarter by voice preference retained tuning in a source nonvocal panel in six SEEG patients and 24 fMRI adults
We reuse its MIT source preparation code, exact author file pins and documented sound class rule. We test a different site preference and nonvocal reliability endpoint.
- usesWith linear acoustic controls, late sound maps from one ECoG panel agreed more with BOLD in 20 adults; an eight-adult check was uncertain
B2021 archive provenance and ten-parcel inclusion workflow.
- usesAt fixed total weight, nonvoice filters failed a shared speech and song test in six SEEG patients and 24 fMRI adults
Its subspace transfer result motivated the test of prediction at fixed total weight.
- Calibrated extra axes reduced mean repeat error in 16-site panels from six SEEG patients and 24 fMRI adults
- Fixed voice direction tests did not confirm shared enrichment after gain removal in six SEEG patients and 16 fMRI adults
Related nonvoice-axis transfer result; the direction of transfer and endpoint differ.