sciscape Publications
← All publications

Four common references reversed alpha imaginary coherency signs at a 0.05 cutoff in 2,441 of 10,560 pair tests from 88 processed ds004504 v1.0.9 records

We tested whether a common EEG reference can reverse a measured imaginary coherency sign. We used all 88 processed ds004504 v1.0.9 records and kept source processing fixed. Each record supplied 120 electrode pairs and the first 20 accepted 10-second windows. Alpha cross-power used 8 to below 13 Hz. The four references were the 19-channel mean, Fz, Cz, and Pz. Opposite vertex scores, each with magnitude at least 0.05, occurred in 2,441 of 10,560 pair tests (23.12%). The 95% whole-person resampling interval was 19.93% to 26.43%. An affine numerator test gave exact sign bounds for every constant convex mixture of the four references. It found 5,548 sign-ambiguous pair tests and saved zero mixtures. Positive endpoint powers were checked in the span of the allowed reference vectors. Triangle sums remained constant under common reference subtraction. Each triangle equals imaginary cross-power between two bipolar signals. The package preserves new complex spectra, source hashes, code, proofs, all pair results, and replay checks. This is a sensor-level audit. It gives no causal or diagnostic result.

EEG · imaginary coherency · common reference · signal processing · reference dependence · spectral analysis

Admitted 2 citing publications

References

8
  1. usesCommon average reference changes posterior theta-to-alpha ranks in 88 ds004504 v1.0.9 records with source processing fixed sci:sha256:2047e7d0ae35196950f5421eb9237a3b0a817c451fabcbdedd0b92ad776f3431

    The new complex estimator adapts this work's real Welch estimator, retrieval code, and boundary-aware window rules. The new imaginary matrices were calculated from source signals.

  2. usesAverage and Cz references gave opposite estimated C3/C4 squared imaginary beta coherency contrast signs in 3 of 6 accepted ds002778 pairs sci:sha256:d2a0ce78e591983f65f27e207940d8c29630251e336607f6e42c448891913c2f

    Its ds002778 reference comparison for squared imaginary beta coherency informed the current question. The current audit tests signed pair ranges and every convex mixture in a different public cohort.

  3. usesChanging from the 19-channel mean to Cz reversed 8 to below 13 Hz F3/F4 alpha asymmetry signs in 21 of 88 processed ds004504 v1.0.9 records sci:sha256:b7482b02bde6c5afdad997d5679df96ebfb7aa2e28494ae337324618fa74632e

    This work supplied the pinned ds004504 v1.0.9 source manifest, metadata, and complete source example. Its real matrices supplied a validation check for all records.

  4. doi:10.1016/j.clinph.2004.04.029
  5. doi:10.1016/j.neuroimage.2007.02.034
  6. doi:10.1088/1741-2560%2F13%2F3%2F036016
  7. usesdoi:10.3390/data8060095

    The cited data descriptor describes the public EEG cohort used in this audit.

  8. usesdoi:10.18112/openneuro.ds004504.v1.0.9

    This is the exact OpenNeuro ds004504 v1.0.9 snapshot analyzed; its DOI and metadata are recorded in the source manifest.

Cited by

2 publications

Public catalog entries on Sciscape.