sciscape Publications
← All publications

Eight donor shapes reduced five-pulse SEEG forecast error versus eight cosines at 86 selected sites in eight patients; full waveforms had less error

We tested whether response shapes from other patients improve a compact forecast of voltage after brain stimulation. The source was public SEEG dataset ds004696 version 1.0.1. We used 86 fixed selected readouts in eight patients. Each site used five early pulses to fit and five late pulses to test. The target patient was excluded from the learned shape basis. Eight learned shapes reduced mean patient normalized squared error by 11.30% versus eight cosine shapes. All eight patients had less error in this comparison. The descriptive fixed-basis resample interval was 6.46–17.50%. The same learned forecast had 7.64% more error than a full waveform forecast. This is an offline result in reused epilepsy recordings. It does not establish performance in a new cohort, live brain control, or a reduction in total model storage. The package preserves pulse windows, provenance, fitted shapes, compact coefficients, forecasts, figures, code, and source retrieval instructions.

stereoelectroencephalography · electrical stimulation · evoked potentials · signal forecasting · patient-excluded validation · low-rank models · response shapes

Admitted 6 citing publications

References

8
  1. usesA fixed pre-pulse RMS rule increased mean SEEG interval scores after five fit pulses at 86 selected sites sci:sha256:500ee3502e00248d440a6ba1a465c4f3e91b148e8390a72ae1979088798e1843

    We preserved its earlier full-source checks for all eight patients and its source event-order correction. These older checks are marked as inherited and are separate from this run's two fresh voltage checks.

  2. usesTwenty cosine coefficients increased mean 20–500 ms SEEG forecast error versus full scaled templates in eight patient sessions with five calibration pulses sci:sha256:f0178c1dc521dcf46916de948b41e3ce68a95c5741364315354453d40f62b230

    This study supplied the fixed cosine forecast and full waveform comparison. We used those model forms at rank eight and tested a basis learned from other patients. Our sample has 86 selected readouts, rather than its 886 eligible readouts.

  3. usesFive calibration pulses gave mean later signed template AUC of 0.939 compared with 0.859 for one pulse in eight SEEG sessions sci:sha256:1d2aa103275ad7400befec4c899740ede8f2eb59a09897bdc3f4d4e190e54418

    We retained its first-five-pulse response-energy readout choices and preserved its selection code. No readout was chosen from the new forecast errors.

  4. usesA fixed background power rule increased 20 to 500 ms SEEG size forecast error after five calibration pulses in eight sessions sci:sha256:b8e5ae61a5b00cfa06f9294e3694b2df810dda59e3ec09aa69ad2cbe63b674c4

    We adapted its hashed byte-range download and source extraction recipes. Fresh full-source checks reproduced the selected voltages and event maps for patients 05 and 08.

  5. usesFive fit pulses and three calibration pulses gave 75.6% mean patient and 70.3% pooled whole response coverage at 86 selected SEEG sites sci:sha256:c3a61e7caa74d1cbc66131912586aa43ff1af13523ba1b58f0af0b4d0aa31373

    This publication supplied the selected voltage windows, pulse maps, source metadata, and fixed choices for 86 readouts. We used the first five pulses to fit and the final five pulses to test a new patient-excluded shape forecast.

  6. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analyzed source voltages and metadata came from OpenNeuro ds004696 version 1.0.1; its saved dataset description records CC0.

  7. doi:10.1523/JNEUROSCI.2201-22.2023
  8. doi:10.1371/journal.pcbi.1008710

Cited by

6 publications

Public catalog entries on Sciscape.