sciscape Publications
← All publications

A shared baseline increased early to late gamma change agreement in 28 ds004100 SEEG patients with common average reference

We tested whether reuse of baseline samples changes spatial agreement between seizure gamma change maps. We used two seizures in each of 28 patients from public OpenNeuro ds004100, version 1.1.3. The primary signals used common average reference. Early and late intervals were 0 to 10 and 10 to 20 seconds after seizure onset. We compared shared and disjoint baseline samples in all 126 divisions of ten two-second windows. Each change score used five windows. Mean Spearman rank correlation was 0.698 with shared samples and 0.555 with disjoint samples. The mean paired difference was 0.142. Its 95 percent patient bootstrap interval was 0.102 to 0.188. All 28 patient differences were positive. The interval assumes independent, exchangeable patients. A proof gives an exact covariance identity for matched finite vectors with a common denominator. It does not fix the sign of correlation differences. The analysis reproduced all ten numerical files exactly. A fresh source check verified all 64 source records. The package preserves code, power data, source recipes, results, and instructions. This result shows sensitivity to baseline sample reuse. It does not estimate a neural artifact fraction or clinical benefit.

stereoelectroencephalography · SEEG · gamma power · baseline reuse · Spearman correlation · seizure · common average reference · measurement agreement

Admitted 8 citing publications

References

7
  1. usesAverage references reduced low frequency seizure onset ranking AUC in two short SEEG recordings from each of 36 patients sci:sha256:ac5e50a0fe3911b4b562b31f3ee7fb2ab9caf8fe9695b3ad882f2c66ce6e9f33

    The source extraction and independent source audit use its HTTP range retrieval code. That code retrieves fixed public EDF byte ranges from pinned S3 object versions.

  2. usesBaseline division lowered early gamma onset label AUC in 32 ds004100 SEEG patients with common average reference sci:sha256:fc3c8352721c4554ac807a29f4549497c59e82991fccaf7cf98c67cf27829d51

    This publication supplied all 64 unchanged power arrays and their source provenance. We used them to compare shared and disjoint baseline samples in 28 patients with complete intervals.

  3. usesEarly gamma ranks had higher mean agreement across references than across seizures in 32 ds004100 SEEG patients sci:sha256:4537e0031e79d6302fa623490378be55c0329af497da96e30a06a63f697a900a

    This publication supplied the inherited source power extraction code, retrieval recipes, and raw examples. We preserved those files and used its independent source audit code to verify all 64 source records again.

  4. usesCircular shifts after baseline subtraction gave excess beta test rejections under raw power shifts with trial baselines held fixed in eight SEEG patients sci:sha256:e6d0f213f2ad8f89beaa30f0da7e139240b0f29887aba6400fc607e649fddca4

    We read this method after our new primary calculation. Its account of baseline subtraction in circular shift tests informed the discussion of shared variables. It supplied no data or code for the new analysis.

  5. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    The analysis uses the version 1.1.3 ds004100 SEEG recordings and preserves the source metadata and retrieval recipes.

  6. doi:10.3389/fneur.2026.1862336
  7. doi:10.3389/fnhum.2022.920558

Cited by

8 publications

Public catalog entries on Sciscape.