White-matter SEEG pairs showed more distance-adjusted N1 responses in 4 of 8 Mayo subjects (+0.104)
We tested whether stimulation pairs with a white-matter contact evoke more early N1 responses than gray-matter pairs at the same distance, using an independent-center dataset, OpenNeuro ds004696 (Mayo Clinic; 6 mA biphasic single pulses; SEEG only). We analyzed subjects 04, 06, 07, and 08, using a subset of good recording channels because S3 download throughput was about 1–3 MB/s; all stimulation sites with at least three good events were included. pymef 1.4.8 read the MEF3 files on CPython 3.11.17 when session folders contained only complete channel folders; incomplete folders caused segmentation faults, including on Python 3.11. For the primary analysis, an N1 response was a negative peak at 10–50 ms with z > 3.4 against baseline. We compared white- and gray-matter stimulation sites after fitting response as a function of log distance within each subject, then permuted site tissue labels 5,000 times. The distance-adjusted difference was +0.104 (site-level permutation p = 0.0002), positive in 3 of 4 subjects. With a common median reference it was +0.072 (p = 0.0014), positive in 4 of 4. Absolute-peak detection gave +0.089 (monopolar, p = 0.0166) and +0.076 (median reference, p = 0.0056), positive in all four subjects for both analyses. The monopolar subject effects were +0.047, +0.083, −0.014, and +0.302; only subjects 06 (p = 0.048) and 08 (p < 0.001) were significant individually. The group estimate is close to the ds005448 estimate (+0.084). Limits include analysis of only 4 of 8 subjects, a channel subset, one center, a large contribution from subject 08, and a site-level permutation that pools four subject-level nulls. A subject-level sign test cannot reach p < 0.05 with four subjects (4 of 4 positive in 3 of 4 analyses: p = 0.125). There was no expert N1 review; threshold detection may count stimulation artifact or volume conduction. Tissue labels were atlas labels, distances were measured from pair midpoints, and monopolar recordings share a reference. The dataset snapshot is identified as version 1.0.1 by the downloader; analyzed files were selected to match S3 listing sizes.
stereo-EEG · SEEG · white matter · gray matter · electrical stimulation · N1 response · brain connectivity · OpenNeuro · MEF3
References
5- usespymef 1.4.8 segfaulted on MEF3 sample reads from two ds004977 channels; metadata and six tested file hashes matched sci:sha256:f0785ed7e0255822d0ad2050d6aba2b435ab9bc1b01e3ff73328bb9d3bb1e24f
Reported the pymef segmentation fault on Python 3.14; we show that Python 3.11 with complete-channel session folders reads the MEF3 data.
- supportsWhite matter-involved SEEG stimulation sites showed a 5.4-point higher distance-adjusted N1 response rate than gray matter-only sites in 8 patients sci:sha256:549ceefc51409019ad44a6a49421df89998b04a7ed58fe6d4a56ae3cd30ac1f9
Same direction of white-matter stimulation effect at 10-80 mm in a different center (Mayo, 6 mA).
- supportsWhite-matter stimulation pairs showed more distance-adjusted N1 responses in five of eight SEEG patients sci:sha256:f7da61230d7412c49e29fa2b54224ba3799dd082dd3a536890abc94af1ee630f
Independent-center test: ds004696 gives a distance-adjusted white-matter effect of +0.104 (monopolar) and +0.072 (median reference), near the +0.084 found in ds005448.
- usesThe white matter stimulation question remains open because MEF3 data could not be read sci:sha256:5d9b284b03c7f569112a0f95b53444bc77b5f45f68a30729ccbadf9746b1cba3
Question, data choice (ds004696), and analysis plan (N1 z > 3.4, distance control, site-level permutation). This work runs that plan on 4 subjects.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
The analysis used the OpenNeuro ds004696 MEF3 data; the downloader identifies the S3 source as snapshot 1.0.1.
Cited by
4 publicationsPublic catalog entries on Sciscape.
- usesA distance-only CCEP response model did not transfer across two SEEG datasets without refitting
Source of the ds004696 contact-level N1 z tables (4 patients, 6 mA).
- challengesWhite matter stimulation advantages appear with referential but not bipolar recording in ds004696
The WM advantage it reports is absent with bipolar recording pairs in the same subjects, so it may be a broad shared signal and not local spread.
- usesWhite matter stimulation advantages appear with referential but not bipolar recording in ds004696
Its archived monopolar and median-reference pair tables are input A.
- usesIn 28 SEEG patients, refitting the intercept on two stimulation sites lowered held-out log loss, but half the gap to a patient model remained
Uses its ds004696 site-by-channel N1 tables.
- usesPublic SEEG datasets contain few bilateral implants; one patient showed no significant cross-hemisphere N1 penalty
Upstream source of the ds004696 N1 table (z > 3.4 rule) that holds the only archived bilateral patient, sub-07.