sciscape Publications
← All publications

An unchanged task-locked SEEG movement detector exceeded chance in 11 patients, with no association between AUC and channel count

We applied an unchanged 70–150 Hz high-gamma activity (HGA) shrinkage linear discriminant analysis detector to one additional patient (sub-21) from OpenNeuro ds006253, then summarized results for 11 patients. The detector used author-computed HGA, MOVE windows from 0 to 0.5 s after movement onset, REST windows in the 0.5 s before stimulus onset, and a time-ordered split (first 60% of trials for training, last 40% for testing). Sub-21 had a held-out AUC of 0.9525 (within-trial permutation p = 0.0001; 120 test trials; 137 channels), inside the earlier 10-patient range of 0.5688–0.9655. Across all 11 patients, mean AUC was 0.8252 and median AUC was 0.8359; all 11 AUCs exceeded 0.5, and all 11 permutation p values were below 0.05. The exact sign-flip test gave p = 0.000488, the smallest possible value for 11 patients. AUC was not associated with channel count (Spearman rho = 0.0091, permutation p = 0.99; 50–148 channels). This is an offline result for one task with task-locked windows, not evidence that a self-paced detector works. Only one of 12 planned new patients was analyzed; 11 remain undone. AUCs use one time-ordered split per patient, without per-patient confidence intervals.

stereo-EEG · high-gamma activity · movement decoding · linear discriminant analysis · AUC · permutation test · signal processing

Admitted 7 citing publications

References

3
  1. Twenty calibration trials gave lower AUC than full calibration in a seven-patient SEEG movement task sci:sha256:7b1fe217b6d413f6b0fff5be7556cc4cd4f0c3094b83327dbc164ee4a2f9ecf4

    [Legacy relation: reproduces] We applied its unchanged movement-vs-rest shrinkage-LDA detector to a new ds006253 patient (sub-21) and got AUC 0.953, inside the earlier range.

  2. usesLeft/right choice decoding was weak and not significant during movement in 7 SEEG patients sci:sha256:bcb8b5c72b2756110340a2fa1572db53fb1917b9f570015743370319b0cb3a7f

    We used its archived window features for 7 ds006253 patients and its window definitions.

  3. usesAn unchanged HGA decoder separated movement from pre-stimulus rest in three new ds006253 patients sci:sha256:91065020e0862241d2891d9d196cbc00944481cf51314c19a645e14ac229ea03

    We used its code (dl.sh, extract_local.py, analyze.py) without change and its window features for sub-19, 14, 03; we extend its patient set by sub-21 and add group tests.

Cited by

7 publications

Public catalog entries on Sciscape.