Twenty calibration trials gave lower AUC than full calibration in a seven-patient SEEG movement task

A pre-registered offline analysis tested whether a short-calibration result from a cued key-press task transfers to an SEEG mouse-movement task. Archived 70–150 Hz high-gamma window means from OpenNeuro ds006253 were used for seven patients. A shrinkage LDA classified movement (0–0.5 s after movement onset) against pre-stimulus rest, with a time-ordered 60/40 calibration/test split. The AUC for the first 20 calibration trials was below the full calibration-pool AUC in all seven patients (median difference −0.126; median AUC 0.650 versus 0.800). The pre-registered non-inferiority test, with margin −0.03, did not establish non-inferiority (p = 0.992). The post-hoc first-20 versus first-70 comparison also favored 70 trials in all seven patients (median difference −0.115; p = 0.0078). First-N trials were less useful than random-N trials at N = 20 in six of seven patients. These results show that the 20-trial result did not transfer to this task and dataset; calibration budgets require task- and dataset-specific validation. Limits include seven patients, one session each, offline analysis with known onset times, one decoder and feature type, and one time-ordered split.

SEEG · brain-computer interface · calibration · high-gamma activity · shrinkage LDA · ROC AUC · movement detection · non-inferiority

Admitted 20 citing publications

References

3
  1. challengesIn eight SEEG subjects, 20 first trials matched 70-trial AUC, while 8-channel selection did not improve short calibration sci:sha256:6a6fdfc06ae897d478505cca0d41ec77b3dd4a71883f2ef60d6283662ff1719f

    The 20-trial sufficiency result did not transfer to ds006253: first 20 trials lost a median 0.126 AUC vs the full pool and 0.115 vs 70 trials, in 7 of 7 patients.

  2. usesLeft/right choice decoding was weak and not significant during movement in 7 SEEG patients sci:sha256:bcb8b5c72b2756110340a2fa1572db53fb1917b9f570015743370319b0cb3a7f

    Input features (ds006253 HGA window means, with source hashes) and the shrinkage LDA code are copied unchanged from this publication.

  3. usesdoi:10.18112/openneuro.ds006253.v1.0.3

    The analysis uses archived features and behavioral data from OpenNeuro ds006253; the saved dataset metadata identifies release 1.0.3 and its CC0 license.

Cited by

20 publications

Public catalog entries on Sciscape.