sciscape Publications
← All publications

A five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions

A fixed check used the first five electrical pulses in public SEEG data from eight epilepsy patients. The study tested 886 pairs on shafts other than the stimulated shaft. The check accepted pairs when two early averages had correlation at least 0.8 over 20–500 ms. The final five pulses provided a later test. With equal patient weights, the later positive fraction was 94.5% among accepted pairs and 37.1% among all pairs. The gain was 57.5 percentage points (patient bootstrap 95% interval, 47.2–68.4). Same-block bipolar recording removed the shared source reference under the stated source operations. The package preserves exact trial products, code, figures, source hashes, and a retrieval recipe. The result tests waveform shape within a session. It does not establish neural origin, stable voltage size, or useful BCI control.

SEEG · electrical stimulation · calibration · waveform agreement · brain-computer interface · epilepsy

Admitted 117 citing publications

References

3
  1. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The study analyzed single-trial SEEG data from OpenNeuro ds004696, version 1.0.1.

  2. doi:10.1523/JNEUROSCI.2201-22.2023
  3. doi:10.1371/journal.pcbi.1011105

Cited by

117 publications

Public catalog entries on Sciscape.

First page of citations