A five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions
A fixed check used the first five electrical pulses in public SEEG data from eight epilepsy patients. The study tested 886 pairs on shafts other than the stimulated shaft. The check accepted pairs when two early averages had correlation at least 0.8 over 20–500 ms. The final five pulses provided a later test. With equal patient weights, the later positive fraction was 94.5% among accepted pairs and 37.1% among all pairs. The gain was 57.5 percentage points (patient bootstrap 95% interval, 47.2–68.4). Same-block bipolar recording removed the shared source reference under the stated source operations. The package preserves exact trial products, code, figures, source hashes, and a retrieval recipe. The result tests waveform shape within a session. It does not establish neural origin, stable voltage size, or useful BCI control.
SEEG · electrical stimulation · calibration · waveform agreement · brain-computer interface · epilepsy
References
3- usesdoi:10.18112/openneuro.ds004696.v1.0.1
The study analyzed single-trial SEEG data from OpenNeuro ds004696, version 1.0.1.
- doi:10.1523/JNEUROSCI.2201-22.2023
- doi:10.1371/journal.pcbi.1011105
Cited by
117 publicationsPublic catalog entries on Sciscape.
- usesEight SEEG sessions gave an uncertain 0.35% mean adjusted energy change between first and final five-pulse groups at 20–500 ms, relative to single-pulse power
The inherited source extraction code originated in this publication. Its remote bipolar contact rules, fixed source windows, and Gram products permit the paired energy analysis. We do not reuse its response-based edge selection.
- usesCycle components of SEEG pulse size ratios were invariant to fixed scalar site gains in six sessions
Used the source extraction method preserved by the pulse-product publication. Its spatial rules, reference cancellation rules, pulse selection code, and public source provenance define the input to this calibration audit.
- usesThree spread pulse records had higher mean normalized 20–100 ms SEEG forecast error than nearby records at equal mean times in eight patients
Uses its fixed cohort of 86 constant-current sites and 886 remote adjacent bipolar readouts. The fresh patient 05 extraction checks its first/final-five products without selecting by the new forecast outcomes.
- usesThe mean ratio of consecutive to arbitrary squared SEEG waveform distances was 0.992 at 20–500 ms in eight patients
Used its fixed site and bipolar readout rules, and its mapping of source waveform rows to chronological pulse records.
- usesRecorded pulse gaps from 2 to 8 seconds had no clear mean SEEG gain relation in eight sessions with site and order controls
Uses its fixed site and pair criteria and source metadata provenance through the template parent.
- usesSite block pooling increased three-pulse SEEG coverage and mean bound score at 20–500 ms in eight patients
Its source extraction lineage defined the public dataset version, derivative sources, adjacent contact readouts, and source quality restrictions used here. The package preserves that lineage and source hashes.
- usesEarlier reverse templates had higher mean error than scaled two-pulse local forecasts in seven limbic SEEG sessions at 20 to 500 ms
Its bipolar cohort and chronological pulse definitions are inherited through the data parent. We preserved those definitions and source provenance.
- usesA scaled pulse triplet kept five-pulse SEEG forecast size bounded under two replacements and increased error in eight unchanged sessions
Its chronological first-five and final-five benchmark supplied the cohort and trial-selection rules.
- usesA fixed 40 Hz projection increased mean later pulse error in eight SEEG sessions used in earlier tests
We use its fixed bipolar limbic cohort, chronological event groups, source hashes, and retrieval rules. The new source audit rebuilds two patients and checks separate later pulses.
- usesLarger response energy was linked to greater later variance relative to baseline in 20–500 ms centered bipolar SEEG from eight patients
This study reused the inspected extraction code and data definitions through publication 17c2fe9b-5fa5-4cc0-8dfc-ed2e4c4edf34. They define same-block bipolar pairs and chronological pulse selection.
- usesA five-pulse geometric median did not show lower normalized SEEG forecast error than noise scaling under one simulated fivefold gain fault in eight patient sessions
We reused the pinned source retrieval and extraction code and the exact Gram-matrix data definition. A fresh source rebuild for one patient matched its data products.
- usesEarly SEEG increased late forecast error in eight patient sessions with five calibration pulses and ridge strength 1
This work supplied the public source extraction method and event identity rules. We preserved its code and used the same eligible SEEG pairs.
- usesSeparate five-pulse profiles had higher mean SEEG spatial error than a shared profile at 20–500 ms in seven patient sessions
This publication first made the exact ten-pulse Gram products and contact tables. We use them unchanged through the direct parent. Its source extraction and chronology work enabled the spatial energy calculation.
- usesWith local time centering, equal windows reversed the mean early SEEG variance difference in eight epilepsy sessions
We used its source extraction and preprocessing audit through the direct parent. Its same-block bipolar method supports cancellation of the shared source reference.
- usesScales from seven donor patients reduced mean late SEEG forecast error by 0.60 percent in eight patient tests with five local calibration pulses
We retained its source-based bipolar pair selection, event-time pulse split, exact trial product format, and extraction provenance. These define the same 886 pairs in eight patient sessions.
- usesA variance stop rule used 46% fewer pulses and raised normalized 20–500 ms centered bipolar SEEG error by 4.5% versus five-pulse scaling in eight sessions
We retain its contact and reference-block rules and its corrected chronological mapping from event rows to source trial indices. These rules define the tested centered bipolar SEEG data.
- usesA fixed 6 Hz phase model increased later SEEG size prediction error versus a fixed mean after five calibration pulses in eight sessions
The extraction code inherits the adjacent-contact bipolar selection and response Gram method from this earlier code source.
- usesEnergy center times met a 10 ms repeatability target less often than peak times in eight limbic SEEG sessions with a 20–500 ms window and a shape check on the first five pulses
We adapted the source extractor and its contact and reference checks. We rebuilt all eight source files and added individual-trial product summaries.
- usesTwo projections gave exact 45-degree phase limits for bounded real future voltage in 430 SEEG windows with fixed linear filtering
Used the original eligible bipolar pair tables and pinned source records, retained through the input study. Selected one readout per site by contact order and verified the fixed pulse choices against public event metadata.
- usesThree-pulse RMS bounds gave mean coverage of 72.2 percent for later SEEG pulses and 38.1 percent for five-pulse sets at 20–500 ms in eight sessions
This work uses the original bipolar product extraction method and archived MATLAB source documentation. They define the eligible readouts, source reference operations, and exact fixed-window waveform product representation.
- usesSEEG variance after mean removal was higher 20 to 500 ms after pulses than before pulses in eight epilepsy sessions
Uses its exact trial waveform products, readout inclusion rules, source metadata, and public extraction code. These inputs permit a comparison of residual variance after pulses with variance before pulses. The present study rebuilds the source products and adds direct variance checks, new outcome calculations, tables, and figures.
- usesIn eight sessions, 33 of 183 later SEEG means that passed a 0.8 shape check failed a voltage size check at a factor of 1.25
We use its exact centered waveform products, metadata, extraction code, and source provenance.
- usesThree spread pulse records had higher mean normalized 20–100 ms SEEG forecast error than nearby records at equal mean times in eight patients
Uses its fixed cohort of 86 constant-current sites and 886 remote adjacent bipolar readouts. The fresh patient 05 extraction checks its first/final-five products without selecting by the new forecast outcomes.
- usesA five-pulse test did not establish lower SEEG size prediction error from pre-pulse RMS in eight patient sessions
We used the bipolar rules for contacts in the same reference block and the five-pulse shape check for a planned subset.
- usesAfter five calibration pulses, about 25 ms template offsets gave a 7.48% mean patient error increase in 100–500 ms SEEG forecasts across eight sessions
We used the adjacent-contact bipolar and spatial exclusion rules inherited through the direct parent. The source rebuild checked these fixed contacts and excluded each stimulated shaft.
- usesFive early SEEG pulses gave an uncertain 4.54-point mean gain over distance for later shape agreement in eight sessions at equal pair counts
We used its compact trial-product representation and source extraction recipe, inherited through the corrected archive. We preserved the recipe and rebuilt patient 08 from the public MATLAB source to check all arrays and tables.
- usesThree SEEG recording pairs share channel hashes and differ in event labels in ds004457 v1.0.2 and ds004696 v1.0.1
The summary of this within-session repeatability check motivated the BCI use of ds004696 pulse-response data. We did not copy its code or derived voltages. We make no claim that it used the two linked releases as independent data.
- usesNominal 90 percent log-size intervals from five early pulses covered 87.1 percent of later pulses at selected SEEG pairs in eight sessions
We reused the exact trial products, source pulse order, spatial rules, source metadata, and extraction code. We added fixed prediction intervals for individual pulse voltage size.
- usesFive-pulse target fraction selection did not show a clear gain over energy selection within stimulation shafts in seven offline SEEG sessions
Used the exact centered bipolar pulse products, all contact tables, source metadata, and the unchanged retrieval and extraction code. These inputs enabled the fixed-panel site comparison and independent source checks.
- usesA five-pulse geometric median had 0.31% higher mean error than a scaled mean for 20–500 ms bipolar SEEG in eight sessions
We used its trial-product extraction code and original event-row mapping through the direct parent. We changed retrieval to curl and rebuilt two public source files to check the inputs.
- usesClipped trial products reduced geometric mean squared forecast error for later 20–500 ms SEEG energy estimates in eight sessions
This source established the public bipolar trial product derivative and extraction rules reused through the voltage parent. The present study uses all retained edges without its response acceptance threshold.
- usesPair selection at 200 to 500 ms did not show a clear SEEG AUC gain with five calibration pulses in eight sessions
This study used its eligible adjacent bipolar pairs and chronological first-five and last-five pulse split. Source metadata checks confirmed those assignments.
- usesFixed noise pooling did not establish lower mean SEEG forecast error at 20–500 ms after five calibration pulses in eight sessions
We used its verified 24 compact input files, chronological pulse split, bipolar readout selection, source metadata, and extraction recipe. They define the same 886 readout instances in eight patient sessions.
- usesAt a 0.8 correlation cutoff, selected bipolar SEEG readouts matched five-pulse means more often than single later pulses in eight sessions
We use the exact trial products, source records, and extraction code from this study. We add a test of individual later pulses and an early individual-pulse check in the same eight patient sessions.
- usesA fixed covariance fit had 6.6 percent more mean squared log error than uniform fits at 20 to 500 ms in six reused SEEG sessions
Used the inherited bipolar contact selection and pulse product extraction method. Source metadata and upstream processing code preserve this provenance.
- usesRecent five-pulse updates with noise scaling reduced mean 20–500 ms centered bipolar SEEG forecast error in eight patient sessions
This work defined the original limbic bipolar pair extraction and first-five and final-five pulse benchmark inherited through the corrected noise-scaling publication.
- usesA five-pulse geometric median had 7.06% higher later 20–500 ms centered bipolar SEEG error than a noise-scaled mean in eight patient sessions
This earlier study supplies the extraction definitions and event-time correction inherited through the immediate parent.
- usesA site blend fitted with five pulses did not establish lower 20–500 ms SEEG forecast error in eight sessions
We reused the public source retrieval and extraction code and the bipolar recording rules through the input parent. These rules define the voltage products and source provenance used in this test.
- usesSelection of time bins from five pulses reduced storage and increased mean later SEEG error at 86 sites in eight reused sessions
We inherited its same-block remote bipolar cohort criteria, event ordering rules, source snapshot, and reference algebra through the waveform parent. The package retains the relevant source metadata and MATLAB code for inspection.
- usesFive later pulses did not establish higher SEEG size correlation for shared contacts than for nearby separate contacts at 20 to 500 ms in eight sessions
Uses the original extraction method, spatial rules, source pins, and GPL extraction code. This run changes download transport and independently rebuilds sub-05 and sub-08.
- usesAt a 0.8 correlation cutoff and a 1.25 size factor, later SEEG means passed shape but failed size in all eight sessions
This study retains the source extraction code, pulse chronology rules, reference rules, and public source provenance from this original SEEG extraction study.
- usesThe order test did not detect excess 20 to 500 ms SEEG waveform change in eight patients
This study used the recording pair rules, pulse selection rules, and extraction recipe that produced the archived waveform products. It retained those rules for a new order contrast.
- usesEarly power selection gave 0.931 mean AUC between later after-pulse and before-pulse SEEG windows in eight epilepsy patient sessions
This study used exact trial waveform products, fixed eligibility rules, extraction code, and pinned provenance from this publication. It added a new early pair-selection comparison and tested later after-versus-before power AUC.
- usesBipolar channel tables did not match EDF labels in 33 public SEEG files from 29 patients
The earlier five-pulse study defines the calibration problem and uses an explicit bipolar construction. This study tests the channel-map input requirement in a separate public dataset. It does not use the earlier voltage data or scores.
- usesFive calibration pulses gave a 4.7-point mean gain over distance for final repeatability of available limbic SEEG pairs in eight sessions at equal pair counts
Its compact waveform archive and extraction method supplied the original data derivative through the directly cited source analysis. We preserve its attribution and code license.
- usesFive early response pulses gave lower mean error for later 20–500 ms sample variance in SEEG from eight people
This study supplies the inherited extraction code and data definitions. They specify adjacent bipolar pairs and separate early and later pulse blocks.
- usesWith a 0.8 correlation cutoff, means of five later pulses matched early templates more often than one later pulse in 196 selected SEEG readouts from eight patient sessions
Used its exact SEEG trial products, source metadata, early five-pulse selection rule, and checked retrieval recipe to test individual later pulses and later-pulse subsets in the same eight patient sessions.
- usesFive later pulses did not establish higher correlation of signed template strengths across shafts after stimulation in eight SEEG sessions
This source extraction set the eligible bipolar readouts, native windows, and first and final pulse groups. Those definitions were reused through the immediate data parent.
- usesIdeal signed scale changes left 84.5 percent of 20–500 ms SEEG error for a fixed five-pulse waveform in eight patient sessions
Uses the inherited source retrieval, chronological pulse split, corrected source row mapping, and same-block adjacent limbic bipolar pair definitions.
- usesAt a 0.8 correlation cutoff and a 1.25 size factor, later SEEG means passed shape but failed size in all eight sessions
This study retains the source extraction code, pulse chronology rules, reference rules, and public source provenance from this original SEEG extraction study.